Search results for " wearable sensor"
showing 7 items of 7 documents
Hankelet-based action classification for motor intention recognition
2017
Powered lower-limb prostheses require a natural, and an easy-to-use, interface for communicating amputee’s motor intention in order to select the appropriate motor program in any given context, or simply to commute from active (powered) to passive mode of functioning. To be widely accepted, such an interface should not put additional cognitive load at the end-user, it should be reliable and minimally invasive. In this paper we present a one such interface based on a robust method for detecting and recognizing motor actions from a low-cost wearable sensor network mounted on a sound leg providing inertial (accelerometer, gyrometer and magnetometer) data in real-time. We assume that the sensor…
A preliminary investigation of the effect of contact pressure on the accuracy of heart rate monitoring by wearable PPG wrist band
2019
The increase of safety and health monitor of workers has become a crucial objective to prevent excessive physical workloads, injuries, accidents and errors. Heart rate (HR) is a very important physiological indicator which could properly describe the workers’ physical status. Recently, wearable photoplethysmographic (PPG) wristband trackers have been utilized to measure HR without hindering normal gesture of workers. However, the quality of PPG signals is highly affected by human physical motions, resulting in a poor reliable HR estimation. Specifically, during different activities and gestures, PPG sensor contact pressures may have an impact on the quality of the heart rate signal. To appr…
Electrochemical detection of chloride ions using Ag-based electrodes obtained from compact disc
2022
Abstract In this work electrochemical sensors fabricated from compact disc material (waste or new) are used to quantify chloride ions in different types of samples. All three electrodes, working, counter, and pseudo-reference electrodes, were fabricated from the compact disc and directly used. Different parameters were studied in order to demonstrate the possibility of using this waste material for efficient and low-cost electrochemical sensors. Chloride sensing performance was evaluated using linear scan voltammetry as the detection technique. A sensitivity of 0.174 mA mM−1 cm−2 with a limit of detection of 20 μM and excellent selectivity against many interferents was observed. Selectivity…
STUDIO E VALIDAZIONE DI SISTEMI PER L’IDENTIFICAZIONE E IL MONITORAGGIO DI PARAMETRI BIOMEDICI ATTI ALLA PREVENZIONE DI EVENTI INDESIDERATI E ALL’ASS…
L’aumento delle patologie cronico-degenerative nella popolazione mondiale ha comportato un numero sempre maggiore di individui richiedenti assistenza sanitaria, generando, nell’ambito delle realtà ospedaliere, diverse problematiche relative al miglioramento della qualità di vita dei pazienti, ai costi e alla gestione di un numero sempre crescente di soggetti ammalati. Il trattamento sanitario e la ricerca di base si sono pertanto orientati verso la prevenzione delle condizioni che predispongono i soggetti ai peggioramenti clinici e ai ricoveri ospedalieri, puntando sia su nuovi sistemi indossabili di monitoraggio per individuare precocemente i segni di peggioramento, sia su sistemi che poss…
A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries
2018
© 2018 SPIE. In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 ± 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with in…
Green and Integrated Wearable Electrochemical Sensor for Chloride Detection in Sweat
2022
Wearable sensors for sweat biomarkers can provide facile analyte capability and monitoring for several diseases. In this work, a green wearable sensor for sweat absorption and chloride sensing is presented. In order to produce a sustainable device, polylactic acid (PLA) was used for both the substrate and the sweat absorption pad fabrication. The sensor material for chloride detection consisted of silver-based reference, working, and counter electrodes obtained from upcycled compact discs. The PLA substrates were prepared by thermal bonding of PLA sheets obtained via a flat die extruder, prototyped in single functional layers via CO2 laser cutting, and bonded via hot-press. The effect of co…
Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis
2023
The aim of the present case report was to provide a longitudinal functional assessment of a patient with transfemoral amputation from the preoperative status with socket-type prosthesis to one year after the osseointegration surgery. A 44 years-old male patient was scheduled for osseointegration surgery 17 years after transfemoral amputation. Gait analysis was performed through 15 wearable inertial sensors (MTw Awinda, Xsens) before surgery (patient wearing his standard socket-type prosthesis) and at 3-, 6-, and 12-month follow-ups after osseointegration. ANOVA in Statistical Parametric Mapping was used to assess the changes in amputee and sound limb hip and pelvis kinematics. The gait symm…